YKS series water-cooled squirrel cage motors are built for mine ventilation and underground drainage applications where heat dissipation is a challenge. In underground mines, ambient temperatures are high and ventilation is limited, so the water-cooled enclosure (ICW81A) removes heat far more effectively than air cooling, allowing higher power density in a compact footprint. The squirrel cage design is inherently robust and maintenance-free, ideal for unattended operation at mine main fans, auxiliary fans and dewatering pumps. Available 220kW-3150kW in 3KV/6KV/10KV with IP44/IP54 protection and Class F insulation. Typical applications: mine main ventilation fans, underground drainage pumps, and cooling water pumps in mining and tunnel projects. Corrosion-resistant construction and sealed terminal boxes suit damp, dusty underground conditions. Each motor is tested per IEC 60034 with full documentation.

The squirrel-cage design is inherently robust and maintenance-free, ideal for unattended operation at mine main fans, auxiliary fans and dewatering pumps. Available from 220kW to 3150kW at 3kV/6kV/10kV with IP44/IP54 protection and Class F insulation.

Typical applications: mine main ventilation fans, underground drainage pumps and cooling-water pumps in mining and tunnel projects.

Selection tip: confirm the cooling-water source, flow and quality, match the protection to the damp, dusty underground site, plan a closed water circuit where water is scarce, and check the temperature rise against the shaft ambient.

Corrosion-resistant construction and sealed terminal boxes suit the damp, dusty underground conditions, and each motor is tested per IEC 60034 with full documentation. FAQ: Why water cooling? For confined or high-temperature sites where air cooling cannot remove enough heat; does it need a water source? Yes, plan adequate supply or a closed loop.

Construction and performance: a water-cooled enclosure with separate internal air and water circuits, sealed terminal boxes, anti-corrosion coating for damp, dusty sites, and a dynamically balanced squirrel-cage rotor on high-capacity rolling bearings. The cooled surface can be cleaned, simplifying underground maintenance.

More applications and answers: also used for tunnels and chemical plants where heat dissipation is limited; on selection, allow for the effect of cooling-water temperature and flow on the output. FAQ: Does the rating fall with water temperature? Yes, size for the worst-case water temperature; what if there is no water? Use a closed water loop or a cooling tower.

Selection and ordering: when ordering, provide the required power, voltage, speed (or speed range), duty and mounting, and confirm the load duty and environment so we can match the frame, cooling and protection; the quotation covers standard accessories, while special voltage, explosion-proof, encoder or marine certification need separate confirmation. Batch orders are negotiable and custom drawings are supported.

FAQ: What is a YKS motor? A HV asynchronous motor with air-to-water cooling (IC81W), for confined or high-power installations.

FAQ: YKS vs YKK? YKS is air-to-water cooled (stronger cooling, higher power), YKK air-to-air cooled.