HomeProductsApplications
GuidesGlobal ReachStandardsExport Selection
NewsFAQAbout UsContact
中文ENРУСESPT
ZZJ Series Rolling Mill Auxiliary DC Motor, power 3.75~186 kW, voltage 220/400V, protection IP23/IP44 product image

Product introduction

The ZZJ800 series are auxiliary-drive DC motors built to the IEC 34-13 standard for auxiliary drives of rolling mills, designed to withstand hard working conditions with frequent starts, stops, reversals and repeated high overloads. They are used on work-roll tables, loopers, shears, pinch rolls and crane hoist and travel drives.

The series has a cylindrical structure with good heat dissipation, a high power-to-weight ratio, and it handles pulsed currents and abrupt load changes while maintaining good commutation. With Class F insulation it is factory-tested to IEC 60034 and can be supplied with a CE certificate.

Available with series, shunt, compound and separate excitation; the S3 intermittent duty has a 5-minute period on the rotor with continuous excitation, and the armature inertia torque tolerance is taken as a positive value.

Selection tip: confirm the duty class (frequent reversing, impact) and the required torque, match the armature voltage to the drive, and pick the frame by torque and duty rather than power alone. For a crane, check the holding brake and the hoisting speed.

FAQ: How does the ZZJ differ from the Z series? The ZZJ is designed specifically for mill and crane auxiliary duty with a more impact-resistant build. Can it replace an existing mill motor? Usually as a drop-in if the frame and shaft match; confirm the dimensions.

Construction and performance: a cylindrical, monobloc frame with a specially treated commutator that withstands frequent starting, and rolling bearings that absorb impact, with the terminal position convenient for wiring. The rotor and commutator carry margin for the current shocks of frequent reversal.

More applications and answers: in metallurgical and crane duty, frequent reversal and heavy load are common, so focus on the duty class and starting torque and check the brake and mechanical match. FAQ: Why DC rather than AC with a VFD? Cranes and mills need high starting torque and a wide constant-torque range, where DC is steadier under heavy reversing duty; does heavy frequent starting shorten life? With the correct duty class and margin it runs reliably for years.

Selection and ordering: when ordering, provide the required power, voltage, speed (or speed range), duty and mounting, and confirm the load duty and environment so we can match the frame, cooling and protection; the quotation covers standard accessories, while special voltage, explosion-proof, encoder or marine certification need separate confirmation. Batch orders are negotiable and custom drawings are supported.

Core Advantages

ZZJ800 Series DC Motor

ZZJ800 crane/metallurgical DC motors, 12 frame sizes, power 3.75~186 kW, with series / compound / shunt-excited windings and S2 / S3 duty. Suitable for hoisting, traversing and closing drives. One row per frame size, per the official datasheet.

12Frame sizes
3.75~186Power (kW)
Series/ShuntField excitation
FrameVentilated continuousEnclosed series (S2)Enclosed intermittent (S3)Airflow
m³/min
Max starting torque (N·m)Max running torque (N·m)GD²
kgf·m²
Max safe
r/min
Weight
kg
Power
kW
Series
r/min
Compound
r/min
Shunt/sep.
r/min
220V
r/min
440V
r/min
Power
kW
Speed
r/min
Series kWSeries r/minCompound kWCompound r/minShunt kWShunt r/minCompound
N·m
Shunt
N·m
Series
N·m
Compound
N·m
Shunt
N·m
Series
N·m
ZZJ-802A3.75900102510251025/20251025/20255.07504.18403.7510803.7511300.0521981571261581231020.53600240
ZZJ-802B5.6800900900900/1800900/18007.56756.07805.69505.610000.0523302702162682101770.753600270
ZZJ-802C7.5800900900900/1800900/180010.06757.58007.19406.710000.0764503602373602802200.753600270
ZZJ-80311.2725800800800/2000800/160014.162011.272510.884010.58800.0947406104006004703601.83300390
ZZJ-80415.0650725725725/1800725/145019.558015.065013.877512.78000.1211008805908806855303.03000550
ZZJ-80622.4575650650650/1950650/130029.050022.457521.269018.67150.1618701500980149011708805.62600870
ZZJ-80837.3525575575575/1725575/115048.545030.05702862526.06300.2034002800186027002150165011.523001030
ZZJ-81052500550550550/1650550/11006744045.05503961533.56000.2550004000270040003100245017.522001250
ZZJ-81275475515515515/1300515/105010042063.55255658045.05650.357450625041506000490037502819001550
ZZJ-814112460500500500/1250500/1000149400865158256563.55600.4211600960064009300750058004817002400
ZZJ-816150450480480480/1200480/960200400112500104540825350.5716000133008900126001040080007516002400
ZZJ-818186410435435435/1100435/870243360138485123490974700.7521700184001230017400144001100011015004300

Back to DC Motors

ZZJ800 model designation

For the model number ZZJ-812:

PositionMeaningExample
ZZJDC motor for rolling-mill auxiliary drivesZZJ
8800 series8
12Frame size12

Features & uses

Structure diagram

ZZJ800 series structure diagram (1.frame 2.fan 3.terminal box 4.field 5.main pole core 6.armature winding 7.brush rocker 8.bearing 9.commutator 10.rotating shaft 11.bearing cover 12.armature 13.endshield 14.compole winding 15.oil nipple 16.compole core 17.nut/washer 18.viewing window)

Characteristic curves

Fig.1 Max running torque of 220V(230V) separately/shunt-excited motors after booster speed regulation
Fig.2 Max running torque of 220V(230V) separately/shunt-excited motors after field-weakening speed regulation
Fig.3 Output power of enclosed intermittent-duty (S3) series-excited motors
Fig.4 Output power of enclosed intermittent-duty (S3) separately/shunt-excited motors

Fig.1 & Fig.2 give the max running torque of separately/shunt-excited motors after booster / field-weakening speed regulation; Fig.3 & Fig.4 give the output power of enclosed intermittent-duty (S3) series- and separately/shunt-excited motors at various duty-cycle (FC) rates. See the outline & mounting drawing below.

Structure, protection & mounting

Shaft dimensions (taper 1:10)

FrameFNUVXFYShaft threadPitchKey width FKey height GD
ZZJ-802111458215.428M302128
ZZJ-803123.5508217.928M363128
ZZJ-804123508217.928M363128
ZZJ-8061436510523.935M4231610
ZZJ-808155.57510527.935M4831811
ZZJ-810161859031.740M5642012
ZZJ-812173959035.240M6442214
ZZJ-814178.511012041.945M8042514
ZZJ-81619112012045.945M9042816
ZZJ-8181991301505040*M10042816

Mounting dimensions

Unit: mm; shaft/base taper 1:10; H is the basic dimension (tolerance 0/-0.5 for 803, 0/-1.0 for 812); the YA~YK lead-wire dimensions apply only when no terminal box is fitted.

FrameABBBLCHABXGKXHBCBDHDVBVCVDVEVFVGYAYEYHYK
ZZJ-802381521831193.5381419952220304.5400221010184121561012721976320
ZZJ-803432597932215.83564571142220342.5444441310216127831012724176335
ZZJ-804457648983228.53814831272220368.5470571310229140701012725476355
ZZJ-8065086981073254.04195331272624393.5521541310260152861012727976385
ZZJ-8085787941200285.54766291303330444.5584511319292165891017831876425
ZZJ-8106228261274311.05216601463330476635541319305178921017834276460
ZZJ-8126869141388339.557272415933305216926416193492101241017837176495
ZZJ-81476210541538374.56358131843936590.57628616193872351401022941376535
ZZJ-81682611871703406.26868892163936660.5829114251940627916810229444114580
ZZJ-81891412641795450.87629912034542698.591898251945730518110229489114625

Outline & mounting dimensions

Outline and mounting dimensions of each frame (unit: mm). Letter dimensions on the drawing include: LC overall length, H centre height, A/B bolt-hole centres, K hole diameter and the 1:10 taper shaft; they match the "Shaft dimensions" and "Mounting dimensions" tables above. Click to enlarge.

ZZJ800 series outline & mounting dimensions

Ordering information

Get a selection & quotation

Send us your motor requirements (power, voltage, speed, frame size) and we will reply with a selection and quotation.

Phone / WhatsApp: +86-15252716628 · Email: [email protected]

Related series

Other series under DC Motor for easy comparison.

Need help selecting? Contact us for a selection & quotation.