It is torque that does the work, not power

People often look only at kW, but torque is what actually turns a heavy load. A high-torque DC motor delivers plenty of turning force even at low speed, which is why it suits cranes, roller tables, mixers and winders - low-speed, heavy-duty jobs.

Torque and speed

rangetorquepower
below base speedconstant (high)rises with speed
above base speedfallsconstant

A DC motor below its base speed runs in the constant-torque region, which is exactly what low-speed heavy duty needs. Above base speed it enters the constant-power region and torque falls with speed.

When you need "high torque"

  • Heavy start - starting fully loaded.
  • Low-speed running - high torque at low speed, direct drive.
  • Frequent reversal - strong commutation.

Converting torque to power

Power (kW) ≈ torque (N·m) × angular speed (rad/s) / 1000, and angular speed = 2π × RPM / 60. So 500 N·m at 120 r/min gives an angular speed of about 12.57 rad/s and a power of about 6.3 kW.

A worked example

A roller table needs 500 N·m at 120 r/min. In the constant-torque region that is about 6.3 kW as above; with a margin, take 7.5 kW, then check the cooling for that low speed. Because it runs slow, a separate blower is likely needed.

What to specify

itemnote
Torque (N·m)required starting / running torque
Speed rangeminimum to maximum
Dutycontinuous / intermittent / frequent start
Coolinglow speed usually needs a blower

Why DC at low speed

An AC motor at low speed usually needs a gearbox to raise torque, or a VFD running at low frequency - which brings iron loss, heat and fall-off in efficiency. A DC motor, by contrast, gives full torque in its constant-torque region without forcing the frequency down, so low-speed heavy duty tends to choose DC.

Wangpai high-torque DC series

See the Z4 (wide range), Z (heavy duty) and ZZJ (mill) ranges.

High-torque DC FAQs

Do I always need a gearbox at low speed? If the DC motor can meet the torque and speed directly, use it (simpler, more efficient); otherwise use a reducer. We can advise on direct versus geared.

Why forced cooling at low speed? At low speed the self-cooling fan turns slowly and moves little air, so a separate blower is fitted. Tell us how much low-speed running you do.

Torque or power - which matters more? It depends: low-speed heavy duty is about torque; high speed is about power. Send us the load torque and we will judge.

Constant torque vs constant power

Understanding the two operating regions is the key to sizing a high-torque motor. Below base speed, the motor runs in the constant-torque region: you can hold high torque at any speed and the power rises with speed. Above base speed, it is the constant-power region: torque falls as speed rises, and the motor can no longer give its full torque at speed. So a low-speed heavy-duty application stays in the constant-torque region and gets its full torque; a high-speed application trades torque for speed.

Choosing between direct and geared

For a given low speed and torque, you can either use a high-torque DC motor directly, or use a smaller, faster motor with a gear reducer. Direct drive is simpler and more efficient, but needs a bigger, lower-speed motor. Geared drive uses a smaller motor but adds the reducer and its losses and maintenance. If the required speed is very low and the torque very high, a reducer is usually more economical. Send us the torque and speed and we will advise.

Common applications

High-torque DC motors are common on roller tables and transfer lines in steel mills, on mixers and agitators in chemical plants, on winders and unwinders in paper and wire lines, and on crane hoists where a heavy load has to be eased into motion at low speed. In each case the motor gives full torque from a near standstill, which is exactly what the process needs.

Checking the cooling

Because the motor runs slowly, its own fan does not push much air. So for sustained low-speed duty, use a separate blower and keep the ventilation clear. In some designs the blower runs continuously whenever the motor is on. If you have a long low-speed duty, tell us and we will specify the cooling.

Sizing example

Say a mixer needs 400 N·m at 90 r/min. The angular speed is about 9.42 rad/s, so the power is about 3.8 kW; with a margin and rounding up, take 5.5 kW. But because the mixer runs at low speed for long periods, we specify a separate blower for cooling. So the answer is not just a kW figure - it is the frame, the cooling and the speed range together.